| Model | SSL-300-12 | SSL-300-15 | SSL-300-24 | SSL-300-36 | SSL-300-48 | |
| Output | DC Voltage | 12V | 15V | 24V | 36V | 48V | 
| Voltage Tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated Current | 25A | 20A | 12.5A | 8.3A | 6.25A | |
| Current Range | 0~25A | 0~20A | 0~12.5A | 0~8.3A | 0~6.25A | |
| Rated Power | 300W | 300W | 300W | 300W | 300W | |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |
| Voltage ADJ. range | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | |
| Setup,rise time | 200ms,80ms/230VAC | |||||
| Hold up time | 20ms/230VAC 16ms/115VAC (at full load) | |||||
| Input | Voltage Range | 90~132VAC or 180~264VAC, 255~370VDC | ||||
| Frequency | 47~63HZ | |||||
| AC Current | 4A/230VAC | |||||
| Efficiency | 83% | 85% | 87% | 87% | 87% | |
| Inrush Current | Cold start 50A/230VAC 30A/115V | |||||
| Leakage Current | < 3.5mA/240VAC | |||||
| Protection | Overload | Rated output power 105%~150% start over load protection | ||||
| protection type:Constant current limiting,recovers automatically after fault condition is removed | ||||||
| Overvoltage | Protection type:Constant voltage limiting, recovers automatically after fault condition is removed | |||||
| Environment | Working temp., humidity | -10℃~+60℃, 20%~90%RH non-condensing | ||||
| Storage temp., humidity | -20℃~+85℃, 10%~95%RH | |||||
| Temp. Coefficient | ±0.03%/℃(0~45℃) | |||||
| Withstand Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min., each along X, Y, Z axes | |||||
| Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/70%RH | |||||
| Compliance | Safety Standard | Compliance to UL1012 | ||||
| EMC Standard | Compliance to EN55022, Class B, EN61000-6-1 | |||||
| Others | Dimension | 308x54x22.5mm(LxWxH) | ||||
| Weight/packing | 0.36kg/50pcs/19kg | |||||
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation.  | 
		|||||